A seven-person Walker's Point crew that tests, repairs, and submits backflow-prevention assemblies for restaurants, clinics, schools, foundries, and multifamily buildings across Milwaukee County. We file your annual paperwork before Milwaukee Water Works sends the second postcard.

Schedule a test   Browse assemblies

The premise

Every commercial water service in Milwaukee has at least one place where the potable supply touches something it shouldn't — a janitor's mop sink with a hose hooked to a chemical jug, a dental vacuum that pulls solids into a saliva ejector, a soda-machine carbonator that lets CO₂ press a copper line back into citric acid, a boiler feed dosed with glycol, a fire-line riser parked under positive pressure. A backflow prevention assembly is the mechanical promise that the city's water moves one way only. The state of Wisconsin requires that promise be inspected, in person, once a year, by a certified tester who carries a calibrated gauge, signs a test report, and submits it to the water purveyor before the deadline.1

That paperwork is what we do. Walker's Point Cross-Connection Co. is a seven-person crew on the second floor of an 1898 Cream-City-brick warehouse on West Florida Street, four blocks from the Milwaukee River and one block from the historic Walker's Point rail siding. We carry an ASSE 5110 backflow-tester credential, an ASSE 5130 repair-technician credential, and an ASSE 5150 trainer credential between us, plus a WI DSPS Master Plumber license that lets us replace a broken assembly the same hour we condemn it. We work on commercial premises only: food service, medical, dental, veterinary, irrigation-with-chemical-injection, fire service, light industrial, and 5-units-and-up multifamily.2

We don't repair water heaters. We don't unclog drains. We don't do residential service calls. What we do is keep a four-drawer steel cabinet of USC FCCCHR-listed rebuild kits in stock, run a thirty-six-week recertification calendar that lines up with each premises type's hazard class, and file annual Milwaukee Water Works test reports on the same day the test is performed — never in batch, never late, never on a postcard ten months overdue.

"Backflow can be back-pressure or back-siphonage. Either way the water doesn't read the arrows on the pipe." — ASSE Series 5000 instructor manual, §2.1

Most recent test cycle

DatePremisesHazardDeviceMfr / ModelSerialResultTester
2026-05-15Three Bridges Medical Group · 2235 S. HowellHighRP · 1"Watts 909WT-449182PassL. Stoltzfus
2026-05-14Escuela de Walker · 312 W. BruceHighRPDA · 4"Wilkins 350ADAZW-77104PassA. Ferraro
2026-05-14Menomonee Valley Foundry · 1110 W. BruceHighRP · 2"Apollo 4ALF-500AP-318822Fail · CK-2 fouledA. Ferraro
2026-05-13Bay View Tap House · 2535 S. KinnickinnicModDC · 3/4"Febco 850FB-227019PassM. Okafor
2026-05-12Mitchell Park Domes · 524 S. LaytonHighRP · 1.5"Watts 909WT-449180Re-test 22 MayL. Stoltzfus
2026-05-11St. Stanislaus Catholic School · 524 W. MitchellModPVB · 1"Febco 765FB-118337PassM. Okafor
2026-05-08Riverwest Co-Op Grocery · 733 E. ClarkeModDC · 1"Wilkins 350ZW-66110PassM. Okafor
2026-05-07Lakefront Brewery · 1872 N. CommerceHighRP · 3"Watts 957WT-228005PassA. Ferraro

All reports filed same-day with Milwaukee Water Works Cross-Connection Control Section. Re-tests scheduled within 10 business days of a Fail finding per MWW §295-1(C)(7).

Assemblies we test

Six assembly families cover ninety-eight percent of Milwaukee's commercial premises. Each entry below links to a data sheet listing the ASSE standard, USC FCCCHR-approved manufacturers and models we keep parts for, the hazard classes the device is appropriate to, the failure modes we look for, and the rebuild interval we recommend.

Type RP · ASSE 1013

Reduced Pressure Principle Assembly

Two checks plus a vented intermediate zone. The only family approved for high-hazard cross-connections — chemical, dental, foundry, dye, irrigation-with-injection.

Hazard: High~$340 test + report
Type DC · ASSE 1015

Double Check Valve Assembly

Two checks in series, no atmospheric vent. Moderate-hazard service: tankless heaters, fire lines without chemical, sealed boilers, secondary irrigation without injection.

Hazard: Moderate~$240 test + report
Type PVB · ASSE 1020

Pressure Vacuum Breaker

Single check plus an air-inlet vent above flood-rim. Common on irrigation laterals; back-pressure-rated only upstream of the last lateral shutoff.

Hazard: High back-siphonage~$185 test + report
Type SVB · ASSE 1056

Spill-Resistant Vacuum Breaker

A PVB with a spring-loaded check that prevents the start-up dribble. Specified on indoor PVB locations where the air-gap discharge would be a nuisance.

Hazard: Back-siphonage~$185 test + report
5/8" meter
Type RPDA · ASSE 1047

Reduced Pressure Detector Assembly

An RP with a parallel 5/8″ bypass meter to log low-flow events — installed on a fire service line so an unauthorized tap shows up on the utility's read.

Hazard: High · Fire service~$520 test + report
5/8" meter
Type DCDA · ASSE 1048

Double Check Detector Assembly

A DC with a parallel detection meter for moderate-hazard fire service. The standard answer for a sprinkler-only fire line carrying no antifreeze and no foam.

Hazard: Moderate · Fire service~$420 test + report
1,418Active accounts
~2,950Tests / year (2025)
3ASSE 5110 testers on roster
98.4%Reports filed same-day
$0Late-fee surcharges in 2025

Work we sign for

  • Annual ASSE 5110 testing

    Scheduled per premises hazard class (high-hazard at 12-month intervals, moderate at 12 with site-by-site review). Five-valve sequence on RP, three-valve on DC, two-valve on PVB. Gauge cert traceable to NIST within 12 months.

  • Repair & rebuild

    ASSE 5130 rebuilds of CK-1, CK-2, and relief-vent diaphragms on Watts 909/957, Wilkins 350/375, Apollo 4ALF, Conbraco 40-200, Febco 825/860. We stock kits for the eleven models that account for 84% of Milwaukee's installed base.

  • New install

    Premise-isolation and containment installs on commercial water services from 3/4″ through 6″. Wall-bracket or pad-mounted with code-required air-gap drains, freeze protection, and access clearance per SPS 382.41(11).

  • Cross-connection hazard survey

    A walking, drawing-based hazard survey of an existing premises. Output: a numbered list of fixtures, hose-bibb tags, and process equipment with required protection level keyed to USC FCCCHR Manual §3.4. The deliverable an AHJ wants to see when there's a question.

  • AHJ submittal & coordination

    We submit your test reports to Milwaukee Water Works on the day they're performed, track the response, and field any rejection. Same in the suburbs: Wauwatosa, West Allis, Glendale, Brown Deer, Greenfield, Mequon, Brookfield each have their own form and their own quirks. We know them.